SOC
SOC
$50.00
To Test Ejaculator
Unit should be fully charged (8 hrs), turn switch to “Test”. Meter should read above 300. Turn switch to “Batt”, turn power switch clockwise until meter reads 50-150. Now plug “SOC” into 3-pin connector on side of unit. Meter should jump to higher reading. Always return power switch to full counter clockwise position.
To Test Probe Cord
With unit still in “Batt” position, plug Probe cord into unit. Turn power switch clockwise until meter reads 50-150. Plug “SOC” into open end of Probe cord. Meter should again jump. Always return Power switch to full counter clockwise position.
Troubleshooting
If the above tests do not pinpoint the problem your probe may be the cause. If the above tests seem satisfactory send the probe in for evaluation to: SPE, 10325 Wadsworth Blvd, Broomfield, CO 80021.
Bull Seems Oversensitive
If this is a problem i.e. young bulls, you may want to reduce the power to the probe. Plug the “SOC” into the unit. Plug the probe cord into the “SOC” then into the probe.